Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Biosensors (Basel) ; 12(1)2021 Dec 29.
Article in English | MEDLINE | ID: covidwho-2276106

ABSTRACT

The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory coronavirus 2 (SARS-CoV-2) is still raging all over the world. Hence, the rapid and sensitive screening of the suspected population is in high demand. The nucleocapsid protein (NP) of SARS-CoV-2 has been selected as an ideal marker for viral antigen detection. This study describes a lateral flow immunoassay (LFIA) based on colloidal gold nanoparticles for rapid NP antigen detection, in which sensitivity was improved through copper deposition-induced signal amplification. The detection sensitivity of the developed LFIA for NP antigen detection (using certified reference materials) under the optimized parameters was 0.01 µg/mL and was promoted by three orders of magnitude to 10 pg/mL after copper deposition signal amplification. The LFIA coupled with the copper enhancement technique has many merits such as low cost, high efficiency, and high sensitivity. It provides an effective approach to the rapid screening, diagnosis, and monitoring of the suspected population in the COVID-19 outbreak.


Subject(s)
COVID-19 , Copper , Coronavirus Nucleocapsid Proteins/isolation & purification , Immunoassay , Metal Nanoparticles , Antibodies, Viral , Gold , Humans , Phosphoproteins , SARS-CoV-2 , Sensitivity and Specificity
2.
J Proteome Res ; 22(4): 1009-1023, 2023 04 07.
Article in English | MEDLINE | ID: covidwho-2288822

ABSTRACT

Mass spectrometry (MS)-based blood proteomics is a crucial research focus in identifying disease biomarkers. Blood serum or plasma is the most commonly used sample for such analysis; however, it presents challenges due to the complexity and dynamic range of protein abundance. Despite these difficulties, the development of high-resolution MS instruments has made comprehensive investigation of blood proteomics possible. The evolution of time-of-flight (TOF) or Orbitrap MS instruments has played a significant role in the field of blood proteomics. These instruments are now among the most prominent techniques for blood proteomics due to their sensitivity, selectivity, fast response, and stability. For optimal results, it is necessary to eliminate high-abundance proteins from the blood sample, to maximize the depth coverage of the blood proteomics analysis. This can be achieved through various methods, including commercial kits, chemically synthesized materials, and MS technologies. This paper reviews recent advancements in MS technology and its remarkable applications in biomarker discovery, particularly in the areas of cancer and COVID-19 studies.


Subject(s)
COVID-19 , Proteomics , Humans , Proteomics/methods , Mass Spectrometry/methods , Proteins/chemistry
3.
Talanta ; 258: 124462, 2023 Jun 01.
Article in English | MEDLINE | ID: covidwho-2276105

ABSTRACT

More than forty antigen testing kits have been approved to response the prevalence of SARS-CoV-2 and its variant strains. However, the approved antigen testing kits are not capable of quantitative detection. Here, we successfully developed a lateral flow immunoassay based on colloidal gold nanoparticles (CGNP-based LFIA) for nucleocapsid (N) protein of SARS-CoV-2 quantitative detection. Delta strain (NMDC60042793) of SARS-CoV-2 have been cultured and analyzed by our developed digital PCR and LFIA methods to explore the relationship between N protein amount and N gene level. It indicated that the linear relationship (y = 47 ×) between N protein molecule number and N gene copy number exhibited very well (R2 = 0.995), the virus titers and N protein amount can be roughly estimated according to nucleic acid testing. Additionally, detection limits (LODs) of nine approved antigen testing kits also have been evaluated according to the Guidelines for the registration review of 2019-nCoV antigen testing reagents. Only three antigen testing kits had LODs as stated in the instructions, the LODs of Kits have been converted into the N gene and N protein levels, according to the established relationships among virus titer vers. N gene and antigen. Results demonstrated that the sensitivity of nucleic acid testing is at least 1835 times higher than that of antigen testing. We expect that the relationship investigation and testing kits evaluation have the important directive significance to precise epidemic prevention.


Subject(s)
COVID-19 , Metal Nanoparticles , Nucleic Acids , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Gold , Nucleocapsid Proteins/genetics , Sensitivity and Specificity
4.
Int J Mol Sci ; 23(17)2022 Sep 01.
Article in English | MEDLINE | ID: covidwho-2023754

ABSTRACT

Carbohydrate antigen 199 (CA199) is a serum biomarker which has certain value and significance in the diagnosis, prognosis, treatment, and postoperative monitoring of cancer. In this study, a lateral flow immunoassay based on europium (III) polystyrene time-resolved fluorescence microspheres (TRFM-based LFIA), integrated with a portable fluorescence reader, has been successfully establish for rapid and quantitative analysis of CA199 in human serum. Briefly, time-resolved fluorescence microspheres (TRFMs) were conjugated with antibody I (Ab1) against CA199 as detection probes, and antibody II (Ab2) was coated as capture element, and a "TRFMs-Ab1-CA199-Ab2" sandwich format would form when CA199 was detected by the TRFM-based LFIA. Under the optimal parameters, the detection limit of the TRFM-based LFIA for visible quantitation with the help of an ultraviolet light was 4.125 U/mL, which was four times lower than that of LFIA based on gold nanoparticles. Additionally, the fluorescence ratio is well linearly correlated with the CA199 concentration (0.00-66.0 U/mL) and logarithmic concentration (66.0-264.0 U/mL) for quantitative detection. Serum samples from 10 healthy people and 10 liver cancer patients were tested to confirm the performances of the point-of-care application of the TRFM-based LFIA, 20.0 U/mL of CA199 in human serum was defined as the threshold for distinguishing healthy people from liver cancer patients with an accuracy of about 60%. The establishment of TRFM-based LFIA will provide a sensitive, convenient, and efficient technical support for rapid screening of CA199 in cancer diagnosis and prognosis.


Subject(s)
Liver Neoplasms , Metal Nanoparticles , Biomarkers, Tumor , Gold , Humans , Immunoassay , Limit of Detection , Microspheres
5.
Biosensors (Basel) ; 12(2)2022 Feb 07.
Article in English | MEDLINE | ID: covidwho-1674496

ABSTRACT

Neutralizing antibody (NAb) is a family of antibodies with special functions, which afford a degree of protection against infection and/or reduce the risk of clinically severe infection. Receptor binding domain (RBD) in the spike protein of SARS-CoV-2, a portion of the S1 subunit, can stimulate the immune system to produce NAb after infection and vaccination. The detection of NAb against SARS-CoV-2 is a simple and direct approach for evaluating a vaccine's effectiveness. In this study, a direct, rapid, and point-of-care bicolor lateral flow immunoassay (LFIA) was developed for NAb against SARS-CoV-2 detection without sample pretreatment, and which was based on the principle of NAb-mediated blockage of the interaction between RBD and angiotensin-converting enzyme 2. In the bicolor LFIA, red and blue latex microspheres (LMs) were used to locate the test and control lines, leading to avoidance of erroneous interpretations of one-colored line results. Under the optimal conditions, NAb against SARS-CoV-2 detection carried out using the bicolor LFIA could be completed within 9 min, and the visible limit of detection was about 48 ng/mL. Thirteen serum samples were analyzed, and the results showed that the NAb levels in three positive serum samples were equal to, or higher than, 736 ng/mL. The LM-based bicolor LFIA allows one-step, rapid, convenient, inexpensive, and user-friendly determination of NAb against SARS-CoV-2 in serum.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , COVID-19 , Antibodies, Neutralizing/isolation & purification , Antibodies, Viral/isolation & purification , COVID-19/diagnosis , Chromatography, Affinity , Humans , Latex , Microspheres , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/immunology
6.
J Virol Methods ; 298: 114285, 2021 12.
Article in English | MEDLINE | ID: covidwho-1401675

ABSTRACT

The ongoing coronavirus disease 2019 (COVID-19) pandemic has become a public health emergency. Although many reverse-transcription PCR (RT-PCR) assays have been developed, their performance, especially sensitivity assessment, has been insufficiently tested. In this study, a preliminary comparison of the analytical sensitivity of nine RT-qPCR kits from different manufacturers was first conducted using a certified reference material derived from the genomic RNA of SARS-CoV-2 as the template. Subsequently, three of the nine kits, comprising two highly sensitive kits (DAAN, Huirui) and one less sensitive kit (Geneodx), were selected for further sensitivity and specificity validation. The results revealed variations in the performance between kits of the two groups. For the two highly sensitive kits, the limits of detection at 95 % probability (LOD95%) were 5.6 copies of the N gene and 3.5 copies of the ORF 1ab per reaction (DAAN), and 6.4 (N) and 4.6 (ORF 1ab) copies per reaction (Huirui). These LOD95% values were approximately 3 to 4-fold better than those of the Geneodx Kit. However, none of these three Kits showed cross-reactivity against 6 other types of human coronaviruses or respiratory viruses. Because most of these commercial kits are approved as in vitro diagnostics (testing specimens without direct human contact), it would be beneficial for their manufacturers to improve the diagnostic capability of these kits and thus reduce the clinical risks associated with false-negative results.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity
8.
Signal Transduct Target Ther ; 6(1): 181, 2021 05 10.
Article in English | MEDLINE | ID: covidwho-1223081

ABSTRACT

Over 40% of the coronavirus disease 2019 (COVID-19) COVID-19 patients were asymptomatically infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the immune responses of these asymptomatic individuals is a critical factor for developing the strategy to contain the COVID-19 pandemic. Here, we determined the viral dynamics and antibody responses among 143 asymptomatic individuals identified in a massive screening of more than 5 million people in eight districts of Wuhan in May 2020. Asymptomatic individuals were admitted to the government-designated centralized sites in accordance with policy. The incidence rate of asymptomatic infection is ~2.92/100,000. These individuals had low viral copy numbers (peaked at 315 copies/mL) and short-lived antibody responses with the estimated diminish time of 69 days. The antibody responses in individuals with persistent SARS-CoV-2 infection is much longer with the estimated diminish time of 257 days. These results imply that the immune responses in the asymptomatic individuals are not potent enough for preventing SARS-CoV-2 re-infection, which has recently been reported in recovered COVID-19 patients. This casts doubt on the efficacy of forming "herd-immunity" through natural SARS-CoV-2 infection and urges for the development of safe and effective vaccines.


Subject(s)
Antibodies, Viral/immunology , Asymptomatic Infections/epidemiology , COVID-19/immunology , Immunity/immunology , Aged , Antibodies, Viral/blood , Antibodies, Viral/genetics , COVID-19/blood , COVID-19/physiopathology , COVID-19/virology , China/epidemiology , Female , Humans , Male , Middle Aged , Pandemics , SARS-CoV-2/immunology , SARS-CoV-2/pathogenicity
9.
Sens Actuators B Chem ; 331: 129415, 2021 Mar 15.
Article in English | MEDLINE | ID: covidwho-1009880

ABSTRACT

The coronavirus disease 2019 (COVID-19) epidemic continues to ravage the world. In epidemic control, dealing with a large number of samples is a huge challenge. In this study, a point-of-care test (POCT) system was successfully developed and applied for rapid and accurate detection of immunoglobulin-G and -M against nucleocapsid protein (anti-N IgG/IgM) and receptor-binding domain in spike glycoprotein (anti-S-RBD IgG/IgM) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Any one of the IgG/IgM found in a sample was identified as positive. The POCT system contains colloidal gold-based lateral flow immunoassay test strips, homemade portable reader, and certified reference materials, which detected anti-N and anti-S-RBD IgG/IgM objectively in serum within 15 min. Receiver operating characteristic curve analysis was used to determine the optimal cutoff values, sensitivity, and specificity. It exhibited equal to or better performances than four approved commercial kits. Results of the system and chemiluminescence immunoassay kit detecting 108 suspicious samples had high consistency with kappa coefficient at 0.804 (P < 0.001). Besides, the levels and alterations of the IgG/IgM in an inpatient were primarily investigated by the POCT system. Those results suggested the POCT system possess the potential to contribute to rapid and accurate serological diagnosis and epidemiological survey of COVID-19.

10.
Talanta ; 224: 121726, 2021 Mar 01.
Article in English | MEDLINE | ID: covidwho-894232

ABSTRACT

The outbreak of COVID-19 caused by a novel Coronavirus (termed SARS-CoV-2) has spread to over 210 countries around the world. Currently, reverse transcription quantitative qPCR (RT-qPCR) is used as the gold standard for diagnosis of SARS-CoV-2. However, the sensitivity of RT-qPCR assays of pharyngeal swab samples are reported to vary from 30% to 60%. More accurate and sensitive methods are urgently needed to support the quality assurance of the RT-qPCR or as an alternative diagnostic approach. A reverse transcription digital PCR (RT-dPCR) method was established and evaluated. To explore the feasibility of RT-dPCR in diagnostic of SARS-CoV-2, a total of 196 clinical pharyngeal swab samples from 103 suspected patients, 77 close contacts and 16 supposed convalescents were analyzed by RT-qPCR and then measured by the proposed RT-dPCR. For the 103 fever suspected patients, 19 (19/25) negative and 42 (42/49) equivocal tested by RT-qPCR were positive according to RT-dPCR. The sensitivity of SARS-CoV-2 detection was significantly improved from 28.2% by RT-qPCR to 87.4% by RT-dPCR. For 29 close contacts (confirmed by additional sample and clinical follow up), 16 (16/17) equivocal and 1 negative tested by RT-qPCR were positive according to RT-dPCR, which is implying that the RT-qPCR is missing a lot of asymptomatic patients. The overall sensitivity, specificity and diagnostic accuracy of RT-dPCR were 91%, 100% and 93%, respectively. RT-dPCR is highly accurate method and suitable for detection of pharyngeal swab samples from COVID-19 suspected patients and patients under isolation and observation who may not be exhibiting clinical symptoms.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , RNA, Viral/analysis , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , Coronavirus Envelope Proteins/genetics , Coronavirus Nucleocapsid Proteins/genetics , Humans , Pharynx/virology , Phosphoproteins/genetics , Polyproteins/genetics , Viral Proteins/genetics
SELECTION OF CITATIONS
SEARCH DETAIL